CEEM A60 Cabin
Optimum Efficiency, Safety & Security
The A60 Office Cabin of CEEM FZE is the first of its kind to be manufactured in its facility. CEEM ensures that the equipment meets various manufacturing international design codes and regulatory requirements.
Considered as an oilfield services equipment, A60 Cabin was manufactured to the highest industry standards DNV 2.7-1, DNV 2.7-2 and ATEX, including compliance with SOLAS/IMO regulatory requirements for A60 fire protection to withstand hostile offshore and marine environments.
The equipment is designed for optimum work efficiency, satisfying environmental, acoustic, safety, and security requirements for your peace of mind.
Standard Technical Specification
- Dimension: 6058mm (L) x 2438mm (W) x 2592mm (H)
- Electrical Input: 380-690V 3 Phase 50/60Hz Electrical Supply
- Electrical Cabling: As per DNV 2.7-2
- Transformer: 23KVA 6 Tap Transformer (1nos)
- Power Outlet Supply: 220v, 110v
- HVAC: Packaged AC (2 Ton working and 2 Ton on standby)
- Total Cooling Capacity: 24000BTU/h
- Total Heating Capacity: 6KW
- Operational Temp Range: -20°C to +55°C
- Output Voltage: 380v/3P/50/60Hz
- CPFG panel: ATEX Approved Exd IIB rated 4 Point Wall mounted
- Fully Automatic Fire and Gas Detection & Shutdown System
- Automatic Fire Dampers with local indication (fail safe), IS Sounder
- Pressurization Fan, Manual Call Point & Pressure Switch
- Gas Detectors H2S (1nos) and HC (2nos)
- Optical Smoke Detector, Heat Detector and Fire Break Glass
- HSE: Fire Extinguishers, First Aid Kit
- A60 Fire rated Insulation: wall, roof & floor
- Flooring: Floating Floor ( Marine Elastic Self-Leveling underlayment & Vinyl Floor Sheet
- A60 Window standard fitted (2nos)
- External Doors: A60 weather tight doors (3nos)
- Internal Door: B15 rated door from Airlock with A60 rated sight glass
- A60 Emergency Escape Hatch
- Furniture: Robust Custom Design of Work Desk, Over Head Cabinets and Chairs
- Painting: 240DFT three coat of marine painting system
- Slings and Shackles: DNV Certified Slings and Shackles with appropriate rating for lifting
- CAT 6 Data/Telephone points
- Certified PA Speaker
Design and Standards
- DNV Approved
- ATEX Compliant
- Structural Design: DNV 2.7-1
- Electrical Design: DNV 2.7-2
- CPFG panel: ATEX Approved Exd IIB rated
- SOLAS Compliant
- Zone 1 and Zone 2
- Area Classification Zone 1
Upgrade and Customizations
Test Cabin, Data Room, Zone 1 / Zone 2 Workshop, Mud Logging Cabin, Well-Site Cabin, Wire Line Support Cabin, Hazardous Material Storage, Ex-rated Telephones, Flat Screen Monitors, UPS, Cabinets and Furniture